Dometic 15000 Brisk Air Ii Manual

0929

3314851.000 Polar White Brisk Air II Air Distribution Box with Manual Controls. This inside ceiling assembly has the knob controls on the unit, meaning that there is no need for a seperate thermostat. It is for use on a non-ducted application, blowing the air straight down. It has been redesigned with a high performance motor and fan, along with fan motor sound dampening brackets to reduce noise and vibration. The EPP foam housing reduces weight and increases cooling performance and it has tighter tolerances for improved fit.

  1. Dometic Brisk Air Ii 15000 Btu Manual

Dometic 13500 Btu Rv Air Conditioner Manual Heat strip for Dometic Brisk Air RV Rooftop Air Toilet Repair Parts, 4-way. Here for 15,000 BTU Brisk Air II.

It has a press fit evaporator cover that eliminates the need for fasteners and makes service access easier. Custom composite Korad shroud is laminated to provide UV protection and the enclosed wrap-around base pan and shroud add strength and protect the coils. It has a 3 inch deep G 90 carbon steel drain pan with a powder-coated finish for durability. This AD Box will only work with the Dometic Brisk II Duo Therm air conditioner 13,500 BTU and the 15,000 BTU AC. Polar White in color.

  1. Buy Dometic 3107206.017 ADB Kit With Manual Control - Polar White: Appliances, Heating. XX1C0 Brisk II Polar White Air Conditioner (15,000 BTU 410A).
  2. Dometic White Brisk Air II 13.5K Air Conditioner. Dometic Polar White Non-Ducted Manual Knob Controlled Ceiling Assembly Kit for New Style Brisk Air II and.

1 per package. State Trailer Supply. BRISK II ADB POLAR WHITE 3314851.000 Polar White Brisk Air II Air Distribution Box with Manual Controls. This inside ceiling assembly has the knob controls on the unit, meaning that there is no need for a seperate thermostat.

It is for use on a non-ducted application, blowing the air straight down. It has been redesigned with a high performance motor and fan, along with fan motor sound dampening brackets to reduce noise and vibration. The EPP foam housing reduces weight and increases cooling performance and it has tighter tolerances for improved fit. It has a press fit evaporator cover that eliminates the need for fasteners and makes service access easier. Custom composite Korad shroud is laminated to provide UV protection and the enclosed wrap-around base pan and shroud add strength and protect the coils. It has a 3 inch deep G 90 carbon steel drain pan with a powder-coated finish for durability. This AD Box will only work with the Dometic Brisk II Duo Therm air conditioner 13,500 BTU and the 15,000 BTU AC.

Dometic

Polar White in color. 1 per package.

$89.00 Store Quantity Availability: Salt Lake City Store: 19 Ogden Store: 29 IDAHO FALLS Store: 15 Peoria Store: 24 Quantity. Summary Item Description 3314851.000 Polar White Brisk Air II Air Distribution Box with Manual Controls. This inside ceiling assembly has the knob controls on the unit, meaning that there is no need for a seperate thermostat. It is for use on a non-ducted application, blowing the air straight down.

It has been redesigned with a high performance motor and fan, along with fan motor sound dampening brackets to reduce noise and vibration. The EPP foam housing reduces weight and increases cooling performance and it has tighter tolerances for improved fit. It has a press fit evaporator cover that eliminates the need for fasteners and makes service access easier. Custom composite Korad shroud is laminated to provide UV protection and the enclosed wrap-around base pan and shroud add strength and protect the coils. It has a 3 inch deep G 90 carbon steel drain pan with a powder-coated finish for durability. This AD Box will only work with the Dometic Brisk II Duo Therm air conditioner 13,500 BTU and the 15,000 BTU AC.

Polar White in color. 1 per package. PDF and Downloads There are no other PDF files or downloads for this item listed at this time. Items: 0 Total: $0.00 State Trailer Supply toll free (877) 978-0400 3600 S.

Redwood Road, Salt Lake City, Utah 84119 Phone: (801)978-0400 3088 S. Washington Blvd., Ogden Utah 84401 Phone: (801)334-0700 2435 N. Yellowstone Highway, Idaho Falls, Idaho 83401 Phone: (208)557-0400 8200 W. Peoria Ave Ste 140, Peoria, Arizona 85345 Phone: (623)412-0400 © 2014-2018 State Trailer Supply, Inc to view our privacy policy.

Periodically (every 2 months for full time users, every 6 months for seasonal campers), remove the return air filter located behind the return air grille and wash it with soap and warm water, let dry and then reinstall. Never run the unit without the return air filter in place. This will plug the unit evaporator coil with dirt and may substantially weaken the performance of the unit over time. Applicable to models: 457915.70X, 640312.80X, 457915.71X, 640312.83X, B57915.71X, 640312C35X, 459516.70X, 640312C85X, 459516.71X, 640315.80X, B59516.71X, 640315.83X, 540315.70X, 640315.84X, 540315.71X, 640315C35X, 540316.70X, 640315C85X, 540316.71X. The heat mode of operation will NOT replace a furnace for heating the RV in cold weather.

The intent is to remove the chill on cool days or mornings. For best results when using your Electric Heater Option:. Turn the selector switch to 'OPT HEAT'. The heat strip will come on and begin heating.

When desired temperature level in RV is reached, move the selector switch to 'OFF' position or 'FAN' position. The thermostat does NOT control the fan/heater ON/OFF cycle.

Applicable to models: 457915.70X, 640312.80X, 457915.71X, 640312.83X, B57915.71X, 640312C35X, 459516.70X, 640312C85X, 459516.71X, 640315.80X, B59516.71X, 640315.83X, 540315.70X, 640315.84X, 540315.71X, 640315C35X, 540316.70X, 640315C85X, 540316.71X. Frost on a small portion of the coil is not unusual.

Under certain conditions, ice may form on the evaporator coil. This is indicated by very cold output at very low air speed and the icing can be seen through the air inlet hole with the filter removed.

If this occurs:. Inspect the filter and clean if dirty. Make sure air vents are open and not obstructed. Units have a greater tendency to frost when the outside temperature is relatively low. This may be prevented by adjusting the thermostat control knob to a warmer setting (counterclockwise). If frosting continues, operate on any FAN ONLY setting until the cooling coil is free of frost.

Then resume normal operation. If frost condition persists, contact your local service center for assistance. Setting the fan to 'HIGH' speed during high humidity/low outside temperature conditions may reduce the chance of frost build up on the fins by maintaining maximum airflow over the coils.

Applicable to models: 457915.70X, 640312.80X, 457915.71X, 640312.83X, B57915.71X, 640312C35X, 459516.70X, 640312C85X, 459516.71X, 640315.80X, B59516.71X, 640315.83X, 540315.70X, 640315.84X, 540315.71X, 640315C35X, 540316.70X, 640315C85X, 540316.71X. The ability of this air conditioner to maintain the desired inside temperature depends on the heat gain of the RV. Some preventive measures taken by the occupants of the RV can reduce the heat gain and improve the performance of the air conditioner.

During extremely high outdoor temperatures, the heat gain of the vehicle may be reduced by:. Parking the RV in a shaded area.

Using window shades (blinds and/or curtains). Keeping windows and doors shut or minimizing usage. Avoiding the use of heat-producing appliances. Operation on High Fan/Cooling mode will give optimum or maximum efficiency in high humidity or high outside temperatures. Starting the air conditioner early in the morning and giving it a “head start” on the expected high outdoor ambient will greatly improve its ability to maintain the desired indoor temperature. For a more permanent solution to high heat gain, accessories like Dometic outdoor patio and window awnings will reduce heat gain by removing direct sunlight. They also add a nice area to enjoy company during the cool of the evening.

Applicable to models: 457915.70X, 640312.80X, 457915.71X, 640312.83X, B57915.71X, 640312C35X, 459516.70X, 640312C85X, 459516.71X, 640315.80X, B59516.71X, 640315.83X, 540315.70X, 640315.84X, 540315.71X, 640315C35X, 540316.70X, 640315C85X, 540316.71X. If your unit fails to operate or operates poorly, check the following before calling a service center:. If RV is connected to a motor generator, check to be sure the motor generator is running and producing power. If RV is connected to power supply by a land line, check to be sure line is sized properly to run unit load and it is plugged into power supply. Check your fuse or circuit breaker to see if it is open. Make sure fuse is not burnt, and make sure circuit breaker has not tripped.

After performing the checks listed above, call your local service center for further help. This unit must be serviced by qualified service personnel only. When calling for service, always provide the following:. Unit model/manufacturer (MFG.) and serial number found on the identification label located on base pan of unit bottom. Return air grille must be removed from air distribution box to view. Air distribution box model and serial number found on rating plate located on ceiling template. Observe this rating plate through the filter opening.

Dometic Brisk Air Ii 15000 Btu Manual

Applicable to models: 457915.70X, 640312.80X, 457915.71X, 640312.83X, B57915.71X, 640312C35X, 459516.70X, 640312C85X, 459516.71X, 640315.80X, B59516.71X, 640315.83X, 540315.70X, 640315.84X, 540315.71X, 640315C35X, 540316.70X, 640315C85X, 540316.71X. The simple answer is yes. For overall best results:. Set the thermostat at the desired temperature level. Select the fan speed that best satisfies your needs:. HIGH COOL: Selected when maximum cooling and dehumidification are required. COOL: Selected when normal or average cooling is required.

LOW COOL: Selected when room is at desired comfort level and needs to be maintained. The blower runs continuously to circulate air and maintain an even temperature. The compressor will come on as cooling is required to maintain the selected temperature level. Wait at least 2 minutes before restarting the compressor when it has been manually cycled off with either the selector switch or the temperature set lever. Otherwise, the compressor will quick-cycle and could result in compressor or supply circuit overload. Applicable to models: 457915.70X, 640312.80X, 457915.71X, 640312.83X, B57915.71X, 640312C35X, 459516.70X, 640312C85X, 459516.71X, 640315.80X, B59516.71X, 640315.83X, 540315.70X, 640315.84X, 540315.71X, 640315C35X, 540316.70X, 640315C85X, 540316.71X + Show all questions.

This entry was posted on 29.09.2019.